PM.001 

Level: UI-ERROR

Short Syntax: PM.001 Fan fan failed.

Long Syntax: PM.001 Cooling fan fan has failed.

Description: A cooling fan has stopped spinning at the minimum RPM required to provide adequate cooling.

PM.002 

Level: U-INFO

Short Syntax: PM.002 Fan fan up to speed.

Long Syntax: PM.002 Cooling fan fan is up to speed.

Description: A cooling fan which had previously failed is now spinning at the minimum RPM required to provide adequate cooling.

PM.003 

Level: U-INFO

Short Syntax: PM.003 Pwr Supp power_supply OFF.

Long Syntax: PM.003 Power Supply power_supply is OFF or has failed.

Description: A power supply has been powered-off or has failed.

PM.004 

Level: U-INFO

Short Syntax: PM.004 Pwr Supp power_supply ON.

Long Syntax: PM.004 Power Supply power_supply is ON.

Description: A power supply has been powered-on.

PM.005 

Level: U-INFO

Short Syntax: PM.005 Thermal thermal Overtemp.

Long Syntax: PM.005 Thermal Sensor thermal is over-temp.

Description: A thermal sensor reading has exceeded the specified threshold.

PM.006 

Level: U-INFO

Short Syntax: PM.006 Thermal thermal below thresh.

Long Syntax: PM.006 Thermal Sensor thermal is below warning level.

Description: A thermal sensor reading which had previously exceeded the specified threshold is now below the specified threshold.

PM.007 

Level: U-INFO

Short Syntax: PM.007 LIC2 at0 at1 - lic_name detected in slot slot.

Long Syntax: PM.007 LIC2 at0 at1 - lic_name detected in slot slot.

Description: A LIC of the type indicated has been detected in the slot indicated.

PM.008 

Level: U-INFO

Short Syntax: PM.008 LIC2 at0 at1 - lic_name extracted from slot slot.

Long Syntax: PM.008 LIC2 at0 at1 - lic_name extracted from slot slot.

Description: A LIC of the type indicated has been extracted from the slot indicated.

PM.009 

Level: UE-ERROR

Short Syntax: PM.009 Mechanical Insertion Error, slot slot.

Long Syntax: PM.009 Mechanical Insertion Error in slot slot.

Description: A mechanical insertion error has occurred indicating that the LIC type could not be detected. Re-inserting the LIC is required.

PM.010 

Level: UE-ERROR

Short Syntax: PM.010 Unknown LIC Type in slot slot.

Long Syntax: PM.010 Unknown LIC Type detected in slot slot.

Description: The LIC type plugged into the slot does not match any known LIC type.

PM.011 

Level: UE-ERROR

Short Syntax: PM.011 LIC2 at0 at1 - lic_name is not valid in slot slot.

Long Syntax: PM.011 LIC2 at0 at1 - lic_name is not valid in slot slot.

Description: The type of the LIC plugged into the slot is not compatible with a LIC present in an adjacent slot. As a result, the LIC will not be enabled and the "Wrong Slot" indicator will be on.

PM.012 

Level: UI-ERROR

Short Syntax: PM.012 LIC2 at0 at1 - lic_name in slot slot is defective.

Long Syntax: PM.012 LIC2 at0 at1 - lic_name in slot slot is defective.

Description: The LIC type plugged into the slot is defective.